Schneider Electric 16A 3P Manual Circuit Breaker
GV2ME/GV3ME series motor protection circuit breakers (Motor Manual Starters) are mainly used for the overload and short circuit protection of the motor in AC 50/60Hz, up to 660V, 0.1-80A power circuit, as a full-voltage starter to start and cut off the motor, under the AC3 load or for the overload and short circuit protection of the circuit and power equipment in the power distribution network
- Delivered today (order Mon-Fri before 12:00, delivery between 17:00 and 22:00)
- Including shipping costs, sent by klbtheme.com
- Pick up at a klbtheme.com collection point is possible
- 30 days to change your mind and free returns
- Day and night customer service
Description
Schneider Electric 16A 3P Manual Circuit Breaker
Motor circuit breaker, TeSys GV2, 3P, 0.25-0.4 A, thermal magnetic, screw clamp terminals
Specifications | |
Starter Overload Amp Setting | 0.25-0.4 Amp |
Component | IEC Starter |
Sub Component | TeSys GV2 Manual Starter and Protector |
Starter Poles | Three Pole |
Manufacturer | Schneider Electric |
Starter Amperage | 0.4 Amp |
Application
GV2ME/GV3ME series motor protection circuit breakers (Motor Manual Starters) are mainly used for the overload and short circuit protection of the motor in AC 50/60Hz, up to 660V, 0.1-80A power circuit, as a full-voltage starter to start and cut off the motor, under the AC3 load or for the overload and short circuit protection of the circuit and power equipment in the power distribution network.
Setting Range of Thermal Trips (A) |
Maximum Horsepower Ratings | GV2ME Pushbutton |
GV2P Rotary Handle |
|||||
Single Phase | Three Phase | |||||||
115V (HP) |
230V (HP) |
200V (HP) |
230V (HP) |
460V (HP) |
575V (HP) |
Catalog Number | Catalog Number | |
0.11 – 0.16 0.016 – 0.25 0.25 – 0.40 0.40 – 0.63 0.63 – 1 1 – 1.6 1.6 – 2.5 2.5 – 4 4 – 6.3 6 – 10 9 – 14 13 – 18 17 – 23 20 – 25 24 – 32 |
– – – – – – – 1/8 1/4 1/2 3/4 1 1-1/2 2 2 |
– – – – – 1/10 1/6 1/3 1/2 1-1/2 2 3 3 3 5 |
– – – – – – 1/2 3/4 1-1/2 2 3 5 5 5 10 |
– – – – – – 1/2 1 1-1/2 3 3 5 7-1/2 7-1/2 10 |
– – – – 1/2 3/4 1 2 3 5 10 10 15 15 20 |
– – – – 1/2 1 1-1/2 3 5 7-1/2 10 15 20 20 30 |
GV2ME01 GV2ME02 GV2ME03 GV2ME04 GV2ME05 GV2ME06 GV2ME07 GV2ME08 GV2ME10 GV2ME14 GV2ME16 GV2ME20 GV2ME21 GV2ME22 GV2ME32 |
GV2P01 GV2P02 GV2P03 GV2P04 GV2P05 GV2P06 GV2P07 GV2P08 GV2P10 GV2P14 GV2P16 GV2P20 GV2P21 GV2P22 |
1 – 1.6 1.6 – 2.5 2.5 – 4 4 – 6 6 – 10 10 – 16 16 – 25 25 – 40 40 – 63 |
– – 1/8 1/4 1/2 1 2 3 5 |
1/10 1/16 1/3 1/2 1-1/2 2 3 7-1/2 10 |
– 1/2 3/4 1-1/2 2 3 5 10 20 |
– 1/2 1 1-1/2 3 5 7-1/2 10 20 |
3/4 1 2 3 5 10 15 30 40 |
1 1-1/2 3 – 7-1/2 10 20 30 60 |
GV3ME06 GV3ME07 GV3ME08 GV3ME10 GV3ME14 GV3ME20 GV3ME25 GV3ME40 GV3ME63 |
Auxiliary Contact Blocks
Picture | Description | Mounting Location |
Max. No. of Blocks |
Contact Type | Catalog Number |
Instantaneous auxiliary contacts GV2ME + GV3P |
Frontbg | 1 | N.O. or N.C. N.O. + N.C. N.O. + N.O. |
GVAE1 GVAE11 GVAE20 |
|
Left Hand Side | 2 | N.O. + N.C. N.O. + N.O. |
GVAN11 GVAN20 |
||
Fault signaling contact + instantaneous auxiliary contact GV2 + GV3P | Left Hand Side | 1 | N.O. (fault) + N.O. N.O. (fault) + N.C. N.C. (fault) + N.O. N.C. (fault) + N.C. | GVAD1010 GVAD1001 GVAD0110 GVAD0101 |
|
Short circuit signaling contact GV2 + GV3P |
Left Hand Side | 1 | SPDT | GVAM11 |
Voltage Trips
– To order an undervoltage trip: replace the bullet (•) with a U (for example, GVAU025).
– To order a shunt trip: replace the bullet (•) with an S (for example, GVAS025).
Picture | Only one trip or fault signaling contact can be installed per GV2ME/GV3ME device | ||||
Description | Characteristics | Voltage | Frequency | Catalog
Number |
|
Voltage trips GV2 & GV3P |
Undervoltage or Shunt trip (external mounting, 1 block right side only) |
24 V | 50 Hz 60 Hz |
GVA•025 GVA•026 |
|
48 V | 50 Hz 60 Hz |
GVA•055 GVA•056 |
|||
100-110 V | 50/60 Hz | GVA•107 | |||
110-115 V | 50 Hz 60 Hz |
GVA•115 GVA•116 |
|||
120-127 V | 50 Hz | GVA•125 | |||
127 V | 60 Hz | GVA•115 | |||
200 V | 50 Hz | GVA•207 | |||
200-220 V | 60 Hz | GVA•207 | |||
220-240 V | 50 Hz 60 Hz |
GVA•225 GVA•226 |
|||
380-400 V | 50 Hz 60 Hz |
GVA•385 GVA•386 |
|||
415-440 V | 50 Hz | GVA•415 | |||
415 V | 60 Hz | GVA•416 | |||
440 V | 60 Hz | GVA•385 | |||
480 V | 60 Hz | GVA•415 | |||
500 V 600 V |
50 Hz 60 Hz |
GVA•505 |
– Mounting of a GVAE contact block or a GV2AK00 visible isolation block on GV2P.
– Choice of N.C. or N.O. contact operation, depending on which way the reversible block is mounted.
– The GVAD is always mounted next to the starter.
– For spring terminals, add 3 to the catalog number (for example, GVAE113).
– One trip or one fault signaling can be fitted per GV3.
– Cannot be used with GV2GH7 insulator.