Schneider Electric 16A 3P Manual Circuit Breaker

In Stock

GV2ME/GV3ME series motor protection circuit breakers (Motor Manual Starters) are mainly used for the overload and short circuit protection of the motor in AC 50/60Hz, up to 660V, 0.1-80A power circuit, as a full-voltage starter to start and cut off the motor, under the AC3 load or for the overload and short circuit protection of the circuit and power equipment in the power distribution network

  • Delivered today (order Mon-Fri before 12:00, delivery between 17:00 and 22:00)
  • Including shipping costs, sent by klbtheme.com
  • Pick up at a klbtheme.com collection point is possible
  • 30 days to change your mind and free returns
  • Day and night customer service

Description

Schneider Electric 16A 3P Manual Circuit Breaker

Motor circuit breaker, TeSys GV2, 3P, 0.25-0.4 A, thermal magnetic, screw clamp terminals

Specifications
Starter Overload Amp Setting 0.25-0.4 Amp
Component IEC Starter
Sub Component TeSys GV2 Manual Starter and Protector
Starter Poles Three Pole
Manufacturer Schneider Electric
Starter Amperage 0.4 Amp

Application

GV2ME/GV3ME series motor protection circuit breakers (Motor Manual Starters) are mainly used for the overload and short circuit protection of the motor in AC 50/60Hz, up to 660V, 0.1-80A power circuit, as a full-voltage starter to start and cut off the motor, under the AC3 load or for the overload and short circuit protection of the circuit and power equipment in the power distribution network.

Setting Range of
Thermal Trips
(A)
Maximum Horsepower Ratings GV2ME
Pushbutton
GV2P
Rotary Handle
Single Phase Three Phase
115V
(HP)
230V
(HP)
200V
(HP)
230V
(HP)
460V
(HP)
575V
(HP)
Catalog Number Catalog Number
0.11 – 0.16
0.016 – 0.25
0.25 – 0.40
0.40 – 0.63
0.63 – 1
1 – 1.6
1.6 – 2.5
2.5 – 4
4 – 6.3
6 – 10
9 – 14
13 – 18
17 – 23
20 – 25
24 – 32







1/8
1/4
1/2
3/4
1
1-1/2
2
2





1/10
1/6
1/3
1/2
1-1/2
2
3
3
3
5






1/2
3/4
1-1/2
2
3
5
5
5
10






1/2
1
1-1/2
3
3
5
7-1/2
7-1/2
10




1/2
3/4
1
2
3
5
10
10
15
15
20




1/2
1
1-1/2
3
5
7-1/2
10
15
20
20
30
GV2ME01
GV2ME02
GV2ME03
GV2ME04
GV2ME05
GV2ME06
GV2ME07
GV2ME08
GV2ME10
GV2ME14
GV2ME16
GV2ME20
GV2ME21
GV2ME22
GV2ME32
GV2P01
GV2P02
GV2P03
GV2P04
GV2P05
GV2P06
GV2P07
GV2P08
GV2P10
GV2P14
GV2P16
GV2P20
GV2P21
GV2P22
1 – 1.6
1.6 – 2.5
2.5 – 4
4 – 6
6 – 10
10 – 16
16 – 25
25 – 40
40 – 63


1/8
1/4
1/2
1
2
3
5
1/10
1/16
1/3
1/2
1-1/2
2
3
7-1/2
10

1/2
3/4
1-1/2
2
3
5
10
20

1/2
1
1-1/2
3
5
7-1/2
10
20
3/4
1
2
3
5
10
15
30
40
1
1-1/2
3

7-1/2
10
20
30
60
GV3ME06
GV3ME07
GV3ME08
GV3ME10
GV3ME14
GV3ME20
GV3ME25
GV3ME40
GV3ME63

Auxiliary Contact Blocks

Picture Description Mounting
Location
Max. No. of
Blocks
Contact Type Catalog Number
Newtrend 4-6.3A Gv2me10 Gv2me10c 6-10A Gv2me14 Gv2me14c 9-14A Gv2me16 Gv2me16c 13-18A Gv2me20 Gv2me20c Motor Manual Starter Protection Circuit Breaker Instantaneous auxiliary contacts
GV2ME + GV3P
Frontbg 1 N.O. or N.C.
N.O. + N.C.
N.O. + N.O.
GVAE1
GVAE11
GVAE20
Left Hand Side 2 N.O. + N.C.
N.O. + N.O.
GVAN11
GVAN20
Newtrend 4-6.3A Gv2me10 Gv2me10c 6-10A Gv2me14 Gv2me14c 9-14A Gv2me16 Gv2me16c 13-18A Gv2me20 Gv2me20c Motor Manual Starter Protection Circuit Breaker Fault signaling contact + instantaneous auxiliary contact GV2 + GV3P Left Hand Side 1 N.O. (fault) + N.O. N.O. (fault) + N.C. N.C. (fault) + N.O. N.C. (fault) + N.C. GVAD1010
GVAD1001
GVAD0110
GVAD0101
Short circuit signaling contact
GV2 + GV3P
Left Hand Side 1 SPDT GVAM11

 

Voltage Trips

– To order an undervoltage trip: replace the bullet (•) with a U (for example, GVAU025).
– To order a shunt trip: replace the bullet (•) with an S (for example, GVAS025).

Picture Only one trip or fault signaling contact can be installed per GV2ME/GV3ME device
Description Characteristics Voltage Frequency    Catalog

Number        

Newtrend 4-6.3A Gv2me10 Gv2me10c 6-10A Gv2me14 Gv2me14c 9-14A Gv2me16 Gv2me16c 13-18A Gv2me20 Gv2me20c Motor Manual Starter Protection Circuit Breaker Voltage trips
GV2 & GV3P
Undervoltage or
Shunt trip
(external mounting,
1 block right side only)
24 V 50 Hz
60 Hz
GVA•025
GVA•026
48 V 50 Hz
60 Hz
GVA•055
GVA•056
100-110 V 50/60 Hz GVA•107
110-115 V 50 Hz
60 Hz
GVA•115
GVA•116
120-127 V 50 Hz GVA•125
127 V 60 Hz GVA•115
200 V 50 Hz GVA•207
200-220 V 60 Hz GVA•207
220-240 V 50 Hz
60 Hz
GVA•225
GVA•226
380-400 V 50 Hz
60 Hz
GVA•385
GVA•386
415-440 V 50 Hz GVA•415
415 V 60 Hz GVA•416
440 V 60 Hz GVA•385
480 V 60 Hz GVA•415
500 V
600 V
50 Hz
60 Hz
GVA•505

– Mounting of a GVAE contact block or a GV2AK00 visible isolation block on GV2P.
– Choice of N.C. or N.O. contact operation, depending on which way the reversible block is mounted.
– The GVAD is always mounted next to the starter.
– For spring terminals, add 3 to the catalog number (for example, GVAE113).
– One trip or one fault signaling can be fitted per GV3.
– Cannot be used with GV2GH7 insulator.
Newtrend 4-6.3A Gv2me10 Gv2me10c 6-10A Gv2me14 Gv2me14c 9-14A Gv2me16 Gv2me16c 13-18A Gv2me20 Gv2me20c Motor Manual Starter Protection Circuit Breaker