Schneider Electric TeSys LC1F225 Contactor
TeSys F contactor, 3 poles (3NO), 225A/690V AC-3, for motor applications up to 110kW@400V. It provides a 120V 60Hz AC coil, bolt terminals for bars or cables with lugs. For high operating rates until 2400 cycles/hour and environments until 55°C, it procures high reliability and durability. It makes installation and maintenance easy thanks to its drawer-mounted coil and a large choice of add-on blocks and accessories (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).
- Delivered today (order Mon-Fri before 12:00, delivery between 17:00 and 22:00)
- Including shipping costs, sent by klbtheme.com
- Pick up at a klbtheme.com collection point is possible
- 30 days to change your mind and free returns
- Day and night customer service
Description
Schneider Electric TeSys LC1F225 Contactor
TeSys F contactor – 3P (3 NO) – AC-3 – <= 440 V 225 A – coil 120 V AC
TeSys F contactor, 3 poles (3NO), 225A/690V AC-3, for motor applications up to 110kW@400V. It provides a 120V 60Hz AC coil, bolt terminals for bars or cables with lugs. For high operating rates until 2400 cycles/hour and environments until 55°C, it procures high reliability and durability. It makes installation and maintenance easy thanks to its drawer-mounted coil and a large choice of add-on blocks and accessories (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).
Specifications
Range | TeSys |
---|---|
Range of product | TeSys F |
Product or component type | Contactor |
Device short name | LC1F |
contactor application | Motor control Resistive load |
Utilisation category | AC-3 AC-4 AC-1 |
poles description | 3P |
[Ue] rated operational voltage | <= 460 V DC <= 690 V AC 50/60 Hz |
[Uc] control circuit voltage | 120 V AC 60 Hz |
[Ie] rated operational current | 315 A (at <40 °C) at <= 440 V AC-1 225 A (at <55 °C) at <= 440 V AC-3 |
[Uimp] rated impulse withstand voltage | 8 kV |
---|---|
[Ith] conventional free air thermal current | 315 A (at 40 °C) |
Rated breaking capacity | 1800 A conforming to IEC 60947-4-1 |
[Icw] rated short-time withstand current | 1800 A 40 °C – 10 s 1000 A 40 °C – 30 s 850 A 40 °C – 1 min 560 A 40 °C – 3 min 440 A 40 °C – 10 min |
Associated fuse rating | 315 A gG at <= 440 V 250 A aM at <= 440 V |
Average impedance | 0.32 mOhm – Ith 315 A 50 Hz |
[Ui] rated insulation voltage | 1000 V conforming to IEC 60947-4-1 1500 V conforming to VDE 0110 group C |
Power dissipation per pole | 32 W AC-1 16 W AC-3 |
Overvoltage category | III |
power pole contact composition | 3 NO |
Motor power kW | 110 kW at 380…400 V AC 50/60 Hz (AC-3) 110 kW at 415 V AC 50/60 Hz (AC-3) 110 kW at 440 V AC 50/60 Hz (AC-3) 129 kW at 500 V AC 50/60 Hz (AC-3) 129 kW at 660…690 V AC 50/60 Hz (AC-3) 63 kW at 220…230 V AC 50/60 Hz (AC-3) 40 kW at 400 V AC 50/60 Hz (AC-4) |
Control circuit voltage limits | Operational: 0.85…1.1 Uc 50/60 Hz (at 55 °C) Drop-out: 0.35…0.55 Uc 50/60 Hz (at 55 °C) |
Mechanical durability | 10 Mcycles |
Inrush power in VA | 970 VA, 60 Hz cos phi 0.3 (at 20 °C) |
Hold-in power consumption in VA | 66 VA, 60 Hz cos phi 0.3 (at 20 °C) |
Maximum operating rate | 2400 cyc/h 55 °C |
Operating time | 20…35 ms closing 7…15 ms opening |
Connections – terminals | Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end Power circuit: bar 2 cable(s) – busbar cross section: 32 x 4 mm Power circuit: lugs-ring terminals 1 cable(s) 185 mm² Power circuit: connector 1 cable(s) 185 mm² Power circuit: bolted connection |
Tightening torque | Control circuit: 1.2 N.m Power circuit: 35 N.m |
mounting support | Plate |
Heat dissipation | 18…24 W |
Standards | IEC 60947-1 EN 60947-1 JIS C8201-4-1 IEC 60947-4-1 EN 60947-4-1 |
product certifications | CCC ABS UL RMRoS DNV RINA CB BV LROS (Lloyds register of shipping) |
Compatibility code | LC1F |
Control circuit type | AC at 60 Hz |
IP degree of protection | IP20 front face with shrouds conforming to IEC 60529 IP20 front face with shrouds conforming to VDE 0106 |
---|---|
Protective treatment | TH |
Ambient air temperature for operation | -5…55 °C |
Ambient air temperature for storage | -60…80 °C |
Permissible ambient air temperature around the device | -40…70 °C |
Height | 197 mm |
Width | 168.5 mm |
Depth | 181 mm |
Operating altitude | 3000 m without derating |
Net weight | 4.75 kg |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 21 cm |
Package 1 Width | 24 cm |
Package 1 Length | 26.5 cm |
Package 1 Weight | 5.47 kg |
Warranty | 18 months |
---|
Reviews