Schneider Electric XPS-AC Preventa Relay
This XPSAC safety module monitors emergency shutdown pushbuttons and limit switches. It meets the requirements of Performance Level PL e/Category 4 conforming to standard EN/ISO 13849-1 and SILCL3 conforming to EN/IEC 61508 and EN/IEC 62061. It can be used for monitoring emergency stop circuits conforming to standards EN/ISO 13850 and EN/IEC 60204-1. It has removable terminals for easier and better control wires tightening, thus improving installation reliability. It has additional solid-state output for communication with PLCs about safety status of your process.
- Delivered today (order Mon-Fri before 12:00, delivery between 17:00 and 22:00)
- Including shipping costs, sent by klbtheme.com
- Pick up at a klbtheme.com collection point is possible
- 30 days to change your mind and free returns
- Day and night customer service
Description
Schneider Electric XPS-AC Preventa Relay
module XPSAC – Emergency stop – 48 V AC
This XPSAC safety module monitors emergency shutdown pushbuttons and limit switches. It meets the requirements of Performance Level PL e/Category 4 conforming to standard EN/ISO 13849-1 and SILCL3 conforming to EN/IEC 61508 and EN/IEC 62061. It can be used for monitoring emergency stop circuits conforming to standards EN/ISO 13850 and EN/IEC 60204-1. It has removable terminals for easier and better control wires tightening, thus improving installation reliability. It has additional solid-state output for communication with PLCs about safety status of your process.
Specifications
Range of product | Preventa Safety automation |
---|---|
Product or component type | Preventa safety module |
safety module name | XPSAC |
safety module application | For emergency stop and switch monitoring |
Function of module | Emergency stop Switch monitoring |
Safety level | Can reach PL e/category 4 conforming to EN/ISO 13849-1 Can reach SILCL 3 conforming to EN/IEC 62061 |
Safety reliability data | MTTFd = 210.4 years conforming to EN/ISO 13849-1 DC > 99 % conforming to EN/ISO 13849-1 PFHd = 3.56E-9 1/h conforming to EN/IEC 62061 |
Type of start | Unmonitored |
Connections – terminals | Captive screw clamp terminals, removable terminal block, 1 x 0.2…1 x 2.5 mm² flexible with cable end, with double bezel Captive screw clamp terminals, removable terminal block, 1 x 0.2…1 x 2.5 mm² solid with cable end, with double bezel Captive screw clamp terminals, removable terminal block, 1 x 0.25…1 x 2.5 mm² flexible with cable end, with double bezel Captive screw clamp terminals, removable terminal block, 2 x 0.2…2 x 1 mm² solid with cable end, with double bezel Captive screw clamp terminals, removable terminal block, 2 x 0.2…2 x 1.5 mm² flexible with cable end, with double bezel Captive screw clamp terminals, removable terminal block, 2 x 0.25…2 x 1 mm² flexible with cable end, with double bezel Captive screw clamp terminals, removable terminal block, 2 x 0.5…2 x 1.5 mm² flexible with cable end, with double bezel |
Output type | Relay instantaneous opening, 3 NO circuit(s), volt-free |
Number of additional circuits | 1 solid state output |
[Us] rated supply voltage | 48 V AC – 15…10 % |
Supply frequency | 50/60 Hz |
---|---|
Maximum power consumption in VA | 6 VA AC |
[Uc] control circuit voltage | 48 V |
Breaking capacity | 180 VA holding AC-15 C300 relay output 1800 VA inrush AC-15 C300 relay output |
Breaking capacity | 1.5 A at 24 V (DC-13) time constant: 50 ms for relay output |
Output thermal current | 6 A per relay for relay output |
[Ith] conventional free air thermal current | 10.5 A |
Associated fuse rating | 4 A gG or gL for relay output conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200 6 A fast blow for relay output conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200 |
Minimum output current | 10 mA for relay output |
Minimum output voltage | 16 V for relay output |
Maximum response time on input open | 100 ms |
[Ui] rated insulation voltage | 300 V (pollution degree 2) conforming to IEC 60947-5-1 300 V (pollution degree 2) conforming to DIN VDE 0110 part 1 |
[Uimp] rated impulse withstand voltage | 4 kV overvoltage category III conforming to IEC 60947-5-1 4 kV overvoltage category III conforming to DIN VDE 0110 part 1 |
Local signalling | 2 LEDs |
Current consumption | 100 mA at 48 V AC on power supply |
mounting support | 35 mm symmetrical DIN rail |
Net weight | 0.21 kg |
Standards | EN 1088/ISO 14119 EN/ISO 13850 EN 60204-1 EN/IEC 60947-5-1 |
---|---|
product certifications | TÜV CSA UL |
IP degree of protection | IP20 (terminals) conforming to EN/IEC 60529 IP40 (enclosure) conforming to EN/IEC 60529 |
Ambient air temperature for operation | -10…55 °C |
Ambient air temperature for storage | -25…85 °C |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Height | 11.9 cm |
Package 1 Width | 2.8 cm |
Package 1 Length | 10.3 cm |
Package 1 Weight | 210.0 g |
Unit Type of Package 2 | S01 |
Number of Units in Package 2 | 16 |
Package 2 Height | 15.0 cm |
Package 2 Width | 15.0 cm |
Package 2 Length | 40.0 cm |
Package 2 Weight | 3.585 kg |
Warranty | 18 months |
---|