Description
Schneider Electric TeSys 25A 3P Contactor with 220V AC control
TeSys D contactor, 3 poles (3NO), for motor control applications up to 25A/690V AC-3/3e (11kW@400V). It provides a 220V 50/60Hz AC coil, 1NO+1NC built-in auxiliary contacts (NC mirror certified), connection by ring-lugs screw terminals. For operating rates until 3600 cycles/hour and environments until 60°C, it procures high reliability and durability. Compact (45mm width), DIN-rail mounting or screw fixing. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).
TeSys Deca contactor,3P(3NO),AC-3/AC-3e,<=440V 25A,220V AC coil,lug-rings
Specifications:
Main
| Range of product |
TeSys Deca |
| Product or component type |
Contactor |
| Device short name |
LC1D |
| contactor application |
Motor control
Resistive load |
| Utilisation category |
AC-1
AC-3
AC-3e |
| poles description |
3P |
| [Ue] rated operational voltage |
Power circuit: <= 690 V AC 25…400 Hz
Power circuit: <= 300 V DC |
| [Ie] rated operational current |
25 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
40 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
25 A (at <60 °C) at <= 440 V AC AC-3e for power circuit |
| [Uc] control circuit voltage |
220 V AC 50/60 Hz |
Complementary
| Motor power kW |
5.5 kW at 220…230 V AC 50/60 Hz
11 kW at 380…400 V AC 50/60 Hz
11 kW at 415…440 V AC 50/60 Hz
15 kW at 500 V AC 50/60 Hz
15 kW at 660…690 V AC 50/60 Hz |
| Motor power hp |
3 hp at 230/240 V AC 50/60 Hz for 1 phase motors
2 hp at 115 V AC 50/60 Hz for 1 phase motors
7.5 hp at 230/240 V AC 50/60 Hz for 3 phases motors
15 hp at 460/480 V AC 50/60 Hz for 3 phases motors
20 hp at 575/600 V AC 50/60 Hz for 3 phases motors
7.5 hp at 200/208 V AC 50/60 Hz for 3 phases motors |
| Compatibility code |
LC1D |
| Pole contact composition |
3 NO |
| Protective cover |
With |
| [Ith] conventional free air thermal current |
10 A (at 60 °C) for signalling circuit
40 A (at 60 °C) for power circuit |
| Irms rated making capacity |
140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
450 A at 440 V for power circuit conforming to IEC 60947 |
| Rated breaking capacity |
450 A at 440 V for power circuit conforming to IEC 60947 |
| [Icw] rated short-time withstand current |
240 A 40 °C – 10 s for power circuit
380 A 40 °C – 1 s for power circuit
50 A 40 °C – 10 min for power circuit
120 A 40 °C – 1 min for power circuit
100 A – 1 s for signalling circuit
120 A – 500 ms for signalling circuit
140 A – 100 ms for signalling circuit |
| Associated fuse rating |
10 A gG for signalling circuit conforming to IEC 60947-5-1
63 A gG at <= 690 V coordination type 1 for power circuit
40 A gG at <= 690 V coordination type 2 for power circuit |
| Average impedance |
2 mOhm – Ith 40 A 50 Hz for power circuit |
| Power dissipation per pole |
3.2 W AC-1
1.25 W AC-3
1.25 W AC-3e |
| [Ui] rated insulation voltage |
Power circuit: 690 V conforming to IEC 60947-4-1
Power circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Signalling circuit: 690 V conforming to IEC 60947-1
Signalling circuit: 600 V CSA certified
Signalling circuit: 600 V UL certified |
| Overvoltage category |
III |
| Pollution degree |
3 |
| [Uimp] rated impulse withstand voltage |
6 kV conforming to IEC 60947 |
| Safety reliability level |
B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
| Mechanical durability |
15 Mcycles |
| Electrical durability |
1.65 Mcycles 25 A AC-3 at Ue <= 440 V
1.4 Mcycles 40 A AC-1 at Ue <= 440 V
1.65 Mcycles 25 A AC-3e at Ue <= 440 V |
| Control circuit type |
AC at 50/60 Hz |
| Coil technology |
Without built-in suppressor module |
| Control circuit voltage limits |
0.3…0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz
0.8…1.1 Uc (-40…60 °C):operational AC 50 Hz
0.85…1.1 Uc (-40…60 °C):operational AC 60 Hz
1…1.1 Uc (60…70 °C):operational AC 50/60 Hz |
| Inrush power in VA |
70 VA 60 Hz cos phi 0.75 (at 20 °C)
70 VA 50 Hz cos phi 0.75 (at 20 °C) |
| Hold-in power consumption in VA |
7.5 VA 60 Hz cos phi 0.3 (at 20 °C)
7 VA 50 Hz cos phi 0.3 (at 20 °C) |
| Heat dissipation |
2…3 W at 50/60 Hz |
| Operating time |
12…22 ms closing
4…19 ms opening |
| Maximum operating rate |
3600 cyc/h 60 °C |
| Maximum operating rate |
3600 cyc/h at 60 °C |
| Connections – terminals |
Control circuit: lugs-ring terminals – external diameter: 8 mm
Power circuit: lugs-ring terminals – external diameter: 10 mm |
| Tightening torque |
Control circuit: 1.7 N.m – on lugs-ring terminals – with screwdriver flat Ø 6 mm M3.5
Control circuit: 1.7 N.m – on lugs-ring terminals – with screwdriver Philips No 2 M3.5
Power circuit: 2.5 N.m – on lugs-ring terminals – with screwdriver flat Ø 8 mm M4
Power circuit: 2.5 N.m – on lugs-ring terminals – with screwdriver Philips No 2 M4
Control circuit: 1.7 N.m – on screw clamp terminals – with screwdriver pozidriv No 2
Power circuit: 2.5 N.m – on screw clamp terminals – with screwdriver pozidriv No 2 |
| Auxiliary contact composition |
1 NO + 1 NC |
| Auxiliary contacts type |
type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
type mirror contact 1 NC conforming to IEC 60947-4-1 |
| Signalling circuit frequency |
25…400 Hz |
| Minimum switching voltage |
17 V for signalling circuit |
| Minimum switching current |
5 mA for signalling circuit |
| Insulation resistance |
> 10 MOhm for signalling circuit |
| Non-overlap time |
1.5 ms on de-energisation between NC and NO contact
1.5 ms on energisation between NC and NO contact |
| mounting support |
Rail
Plate |
Environment
| Standards |
CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 60947-4-1
IEC 60335-1:Clause 30.2
IEC 60335-2-40:Annex JJ
UL 60335-2-40:Annex JJ
CSA C22.2 No 60947-4-1 |
| Product certifications |
UL
CCC
CSA
Marine
UKCA
EAC
CB Scheme |
| IP degree of protection |
IP20 front face conforming to IEC 60529 |
| Protective treatment |
TH conforming to IEC 60068-2-30 |
| Climatic withstand |
conforming to IACS E10 exposure to damp heat
conforming to IEC 60947-1 Annex Q category D exposure to damp heat |
| Permissible ambient air temperature around the device |
-40…60 °C
60…70 °C with derating |
| Operating altitude |
0…3000 m |
| Fire resistance |
850 °C conforming to IEC 60695-2-1 |
| Flame retardance |
V1 conforming to UL 94 |
| Mechanical robustness |
Vibrations contactor open (2 Gn, 5…300 Hz)
Vibrations contactor closed (4 Gn, 5…300 Hz)
Shocks contactor closed (15 Gn for 11 ms)
Shocks contactor open (8 Gn for 11 ms) |
| Height |
85 mm |
| Width |
45 mm |
| Depth |
92 mm |
| Net weight |
0.37 kg |
Packing Units
| Unit Type of Package 1 |
PCE |
| Number of Units in Package 1 |
1 |
| Package 1 Height |
12 cm |
| Package 1 Width |
9.5 cm |
| Package 1 Length |
5.5 cm |
| Package 1 Weight |
434 g |
| Unit Type of Package 2 |
S02 |
| Number of Units in Package 2 |
16 |
| Package 2 Height |
15 cm |
| Package 2 Width |
30 cm |
| Package 2 Length |
40 cm |
| Package 2 Weight |
7.489 kg |
Contractual warranty
| Warranty |
18 months |