Schneider Electric XPS-AC Preventa Relay
This XPSAC safety module monitors emergency shutdown pushbuttons and limit switches. It meets the requirements of Performance Level PL e/Category 4 conforming to standard EN/ISO 13849-1 and SILCL3 conforming to EN/IEC 61508 and EN/IEC 62061. It can be used for monitoring emergency stop circuits conforming to standards EN/ISO 13850 and EN/IEC 60204-1. It has removable terminals for easier and better control wires tightening, thus improving installation reliability. It has additional solid-state output for communication with PLCs about safety status of your process.
- Delivering: We offer Nationwide Delivery - Monday - Saturday
- Call: +2348063316412
- Customer Care: We offer technical support and after sales service
- Address: Shop F464 F-Line Industrial Section, Alaba International Market, Ojo, Lagos State, Nigeria.
Description
Schneider Electric XPS-AC Preventa Relay
module XPSAC – Emergency stop – 48 V AC
This XPSAC safety module monitors emergency shutdown pushbuttons and limit switches. It meets the requirements of Performance Level PL e/Category 4 conforming to standard EN/ISO 13849-1 and SILCL3 conforming to EN/IEC 61508 and EN/IEC 62061. It can be used for monitoring emergency stop circuits conforming to standards EN/ISO 13850 and EN/IEC 60204-1. It has removable terminals for easier and better control wires tightening, thus improving installation reliability. It has additional solid-state output for communication with PLCs about safety status of your process.
Specifications
| Range of product | Preventa Safety automation |
|---|---|
| Product or component type | Preventa safety module |
| safety module name | XPSAC |
| safety module application | For emergency stop and switch monitoring |
| Function of module | Emergency stop Switch monitoring |
| Safety level | Can reach PL e/category 4 conforming to EN/ISO 13849-1 Can reach SILCL 3 conforming to EN/IEC 62061 |
| Safety reliability data | MTTFd = 210.4 years conforming to EN/ISO 13849-1 DC > 99 % conforming to EN/ISO 13849-1 PFHd = 3.56E-9 1/h conforming to EN/IEC 62061 |
| Type of start | Unmonitored |
| Connections – terminals | Captive screw clamp terminals, removable terminal block, 1 x 0.2…1 x 2.5 mm² flexible with cable end, with double bezel Captive screw clamp terminals, removable terminal block, 1 x 0.2…1 x 2.5 mm² solid with cable end, with double bezel Captive screw clamp terminals, removable terminal block, 1 x 0.25…1 x 2.5 mm² flexible with cable end, with double bezel Captive screw clamp terminals, removable terminal block, 2 x 0.2…2 x 1 mm² solid with cable end, with double bezel Captive screw clamp terminals, removable terminal block, 2 x 0.2…2 x 1.5 mm² flexible with cable end, with double bezel Captive screw clamp terminals, removable terminal block, 2 x 0.25…2 x 1 mm² flexible with cable end, with double bezel Captive screw clamp terminals, removable terminal block, 2 x 0.5…2 x 1.5 mm² flexible with cable end, with double bezel |
| Output type | Relay instantaneous opening, 3 NO circuit(s), volt-free |
| Number of additional circuits | 1 solid state output |
| [Us] rated supply voltage | 48 V AC – 15…10 % |
| Supply frequency | 50/60 Hz |
|---|---|
| Maximum power consumption in VA | 6 VA AC |
| [Uc] control circuit voltage | 48 V |
| Breaking capacity | 180 VA holding AC-15 C300 relay output 1800 VA inrush AC-15 C300 relay output |
| Breaking capacity | 1.5 A at 24 V (DC-13) time constant: 50 ms for relay output |
| Output thermal current | 6 A per relay for relay output |
| [Ith] conventional free air thermal current | 10.5 A |
| Associated fuse rating | 4 A gG or gL for relay output conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200 6 A fast blow for relay output conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200 |
| Minimum output current | 10 mA for relay output |
| Minimum output voltage | 16 V for relay output |
| Maximum response time on input open | 100 ms |
| [Ui] rated insulation voltage | 300 V (pollution degree 2) conforming to IEC 60947-5-1 300 V (pollution degree 2) conforming to DIN VDE 0110 part 1 |
| [Uimp] rated impulse withstand voltage | 4 kV overvoltage category III conforming to IEC 60947-5-1 4 kV overvoltage category III conforming to DIN VDE 0110 part 1 |
| Local signalling | 2 LEDs |
| Current consumption | 100 mA at 48 V AC on power supply |
| mounting support | 35 mm symmetrical DIN rail |
| Net weight | 0.21 kg |
| Standards | EN 1088/ISO 14119 EN/ISO 13850 EN 60204-1 EN/IEC 60947-5-1 |
|---|---|
| product certifications | TÜV CSA UL |
| IP degree of protection | IP20 (terminals) conforming to EN/IEC 60529 IP40 (enclosure) conforming to EN/IEC 60529 |
| Ambient air temperature for operation | -10…55 °C |
| Ambient air temperature for storage | -25…85 °C |
| Unit Type of Package 1 | PCE |
|---|---|
| Number of Units in Package 1 | 1 |
| Package 1 Height | 11.9 cm |
| Package 1 Width | 2.8 cm |
| Package 1 Length | 10.3 cm |
| Package 1 Weight | 210.0 g |
| Unit Type of Package 2 | S01 |
| Number of Units in Package 2 | 16 |
| Package 2 Height | 15.0 cm |
| Package 2 Width | 15.0 cm |
| Package 2 Length | 40.0 cm |
| Package 2 Weight | 3.585 kg |
| Warranty | 18 months |
|---|